HGS Products HG-11 Sensor Responses

Coil and shunt resistance values affect the sensitivity, damping and pole values. To calculate poles, zeros and sensitivities for sensors built with other resistor values, click here.

Note:

These responses assume that the input resistance of the attached amplifier or datalogger is at least 2 orders of magnitude larger than the parallel sum of the coil and shunt resistances. If this is not the case, total damping will not be 70% and the poles will not describe the system accurately.

Manufacturer Model Frequency / Period Coil Resistance Shunt Resistance Sensitivity RESP Filename Source Comments
HGS Products HG-11 30 Hz / 0.033 s 360 Ohms None 30 V/M/S RESP.XX.NS595..SLZ.HG11.360.NONE.30.30 HGS Products
HGS Products HG-11 30 Hz / 0.033 s 360 Ohms 1300 Ohms 23.49 V/M/S RESP.XX.NS596..SLZ.HG11.360.1300.30.23_49 HGS Products
HGS Products HG-11 30 Hz / 0.033 s 360 Ohms 4700 Ohms 27.87 V/M/S RESP.XX.NS597..SLZ.HG11.360.4700.30.27_87 HGS Products

Mary Templeton 2/21/2019