HGS Products HG-24 Sensor Responses

Coil and shunt resistance values affect the sensitivity, damping and pole values. To calculate poles, zeros and sensitivities for sensors built with other resistor values, click here.

Note:

These responses assume that the input resistance of the attached amplifier or datalogger is at least 2 orders of magnitude larger than the parallel sum of the coil and shunt resistances. If this is not the case, total damping will not be 70% and the poles will not describe the system accurately.

Manufacturer Model Frequency / Period Coil Resistance Shunt Resistance Sensitivity RESP Filename Source Comments
HGS Products HG-24 10 Hz / 0.1 s 375 Ohms None 28.8 V/M/S RESP.XX.NS598..SLZ.HG24.375.NONE.10.28_8 HGS Products
HGS Products HG-24 10 Hz / 0.1 s 375 Ohms 1000 Ohms 20.95 V/M/S RESP.XX.NS599..SLZ.HG24.375.1000.10.20_95 HGS Products
HGS Products HG-24 10 Hz / 0.1 s 375 Ohms 1339 Ohms 22.5 V/M/S RESP.XX.NS600..SLZ.HG24.375.1339.10.22_5 HGS Products

Mary Templeton 2/21/2019