HGS Products HG-24HS Sensor Responses

Coil and shunt resistance values affect the sensitivity, damping and pole values. To calculate poles, zeros and sensitivities for sensors built with other resistor values, click here.

Note:

These responses assume that the input resistance of the attached amplifier or datalogger is at least 2 orders of magnitude larger than the parallel sum of the coil and shunt resistances. If this is not the case, total damping will not be 70% and the poles will not describe the system accurately.

Manufacturer Model Frequency / Period Coil Resistance Shunt Resistance Sensitivity RESP Filename Source Comments
HGS Products HG-24HS 10 Hz / 0.1 s 1800 Ohms None 85.8 V/M/S RESP.XX.NS603..SLZ.HG24HS.1800.NONE.10.85_8 HGS Products
HGS Products HG-24HS 10 Hz / 0.1 s 1800 Ohms 20000 Ohms 78.72 V/M/S RESP.XX.NS604..SLZ.HG24HS.1800.20000.10.78_72 HGS Products

Mary Templeton 2/21/2019