Trillium Slim Posthole 120 Nanometrics Nominal Trillium Sensor Responses

Nanometrics Trillium Sensors

Trillium Models and Generations

There are several Trillium seismometer models that are represented by the same response, for example the Trillium 120Q or QA vault, Trillium 120 Posthole and Trillium 120 Borehole models, all of which are represented by the Trillium 120Q responses. Some Trillium sensors have been built with different feedback electronics over time. These changes are referred to as "generations" and can be determined by serial number. The table below shows this correlation.

Model Generation Serial Numbers
Trillium 120 Posthole,
Trillium 120 Borehole,
Trillium 120Q,
Trillium 120QA
1 0-99
2 100-199
3 200 and above
Trillium 240 1 0-399
2 400 and above

The Trillium Cascadia Posthole contains a Trillium Compact seismometer and a Titan accelerometer. Please use the Titan responses for this accelerometer.

Manufacturer Model Electronics Period / Frequency Sensitivity RESP Filename Source Comments
Nanometrics Trillium 40 40 s / 0.025 Hz 1553 V/M/S RESP.XX.NS120..BHZ.Trillium40.40.1553 Nanometrics
Nanometrics Trillium 120P/PA 120 s / 0.00833 Hz 1201 V/M/S RESP.XX.NS121..BHZ.Trillium120P.120.1201 Nanometrics T120-P-SV1,T120-PA-SV1
Nanometrics Trillium 120Q/QA,PH,BH generation 1 120 s / 0.0083 Hz 1201 V/M/S RESP.XX.NS354..BHZ.Trillium120Q_g1.120.1201 Nanometrics T120PH
Nanometrics Trillium 120Q/QA,PH,BH generation 2 120 s / 0.0083 Hz 1201 V/M/S RESP.XX.NS355..BHZ.Trillium120Q_g2.120.1201 Nanometrics T120-B1/T120BH1,T120-PH1,T120-PH2
Nanometrics Trillium 120Q/QA,PH,BH generation 3 120 s / 0.0083 Hz 1203 V/M/S RESP.XX.NS331..BHZ.Trillium120Q_g3.120.1203 Nanometrics T120-B1/T120-BH1,T120-B1-XH/T120-BH1-XH,T120-OBS1,T120-PH1,T120-PH1-XC,T120-PH2,T120-PH2-XC
Nanometrics Trillium 120Q/QA,PH,BH 120 s / 0.0083 Hz 1500 V/M/S RESP.XX.NS539..BHZ.Trillium120Q.120.1500 Nanometrics T120-B1-1500/T120-BH1-1500,T120-PH1-1500,T120-Q-SV1-1500,T120-QA-SV1-1500
Nanometrics Trillium 120Q/QA,PH,BH 120 s / 0.0083 Hz 2013 V/M/S RESP.XX.NS540..BHZ.Trillium120Q.120.2013 Nanometrics T120-QA-SV1-2000
Nanometrics Trillium Horizon 120 120 s / 0.0083 Hz 1203 V/M/S RESP.XX.NS690..BHZ.TrilliumHorizon120.120.1203 Nanometrics TH120-1,TH120-1-XC
Nanometrics Trillium Horizon 120 V2 120 s / 0.0083 Hz 1203 V/M/S RESP.XX.NS691..BHZ.TrilliumHorizon120V2.120.1203 Nanometrics TH120-2,TH120-2-XC,TH120-2-M,T120-SPH2,T120-SPH2-XC
Nanometrics Trillium Horizon 120 V2 120 s / 0.0083 Hz 1500 V/M/S RESP.XX.NS539..BHZ.Trillium120Q.120.1500 Nanometrics TH120-SPH2-1500
Nanometrics Trillium Horizon 120 V2 120 s / 0.0083 Hz 2000 V/M/S RESP.XX.NS692..BHZ.TrilliumHorizon120V2.120.2000 Nanometrics TH120-SPH2-2000
Nanometrics Trillium Compact 20 Vault,PH,OBS 20 s / 0.05 Hz 753 V/M/S RESP.XX.NS348..BHZ.TrilliumCompact20.20.753 Nanometrics TC20-PH1,TC20-PH2,TC20-PH2-XH,TC20-SV1,TCH20-1,TCSH20-1-XC,TC20-PH2-XC
Nanometrics Trillium Compact 20 Vault,PH,OBS 20 s / 0.05 Hz 1500 V/M/S RESP.XX.NS544..BHZ.TrilliumCompact20.20.1500 Nanometrics TC20-PH2-1500,TCH20-1-1500,TCH20-1-1500-XC
Nanometrics Trillium Compact 20 Vault,PH,OBS 20 s / 0.05 Hz 2000 V/M/S RESP.XX.NS693..BHZ.TrilliumCompact20.20.2000 Nanometrics TC20-PH2-2000,TCH20-1-2000,TCH20-1-2000-XC
Nanometrics Trillium Compact 20 Vault,PH,OBS 20 s / 0.05 Hz 3000 V/M/S RESP.XX.NS694..BHZ.TrilliumCompact20.20.3000 Nanometrics TC20-PH2-3000,TCH20-1-3000,TCH20-1-3000-XC
Nanometrics Trillium Compact 120 Vault,PH,OBS 120 s / 0.0083 Hz 754 V/M/S RESP.XX.NS124..BHZ.TrilliumCompact120.120.754 Nanometrics TC120-AT1,TC120-OBSA1,TC120-OBSM1,TC120-OBSM2,TC120-OBST1,TC120-OBST2,TC120-PH1,TC120-PH2,TC120-PH2-XC,TC120-PH2-XH,TC120-SV1,TCH120-1,TCH120-1-XC
Nanometrics Trillium Compact 120 Vault,PH,OBS 120 s / 0.0083 Hz 1500 V/M/S RESP.XX.NS543..BHZ.TrilliumCompact120.120.1500 Nanometrics TC120-PH2-1500,TC120-SV1-1500,TCH120-1-1500,TCH120-1-1500-XC
Nanometrics Trillium Compact 120 Vault,PH,OBS 120 s / 0.0083 Hz 2000 V/M/S RESP.XX.NS695..BHZ.TrilliumCompact120.120.2000 Nanometrics TC120-PH2-2000,TCH120-1-2000-XC
Nanometrics Trillium All-Terrain 120 s / 0.0083 Hz 754 V/M/S RESP.XX.NS124..BHZ.TrilliumCompact120.120.754 Nanometrics TC120-AT1,TC120-OBSA1,TC120-OBSM1,TC120-OBSM2,TC120-OBST1,TC120-OBST2,TC120-PH1,TC120-PH2,TC120-PH2-XC,TC120-PH2-XH,TC120-SV1,TCH120-1,TCH120-1-XC
Nanometrics Trillium Cascadia 120 s / 0.0083 Hz 754 V/M/S RESP.XX.NS124..BHZ.TrilliumCompact.120.754 Nanometrics Onboard seismometer. TC120-AT1,TC120-OBSA1,TC120-OBSM1,TC120-OBSM2,TC120-OBST1,TC120-OBST2,TC120-PH1,TC120-PH2,TC120-PH2-XC,TC120-PH2-XH,TC120-SV1,TCH120-1,TCH120-1-XC
Nanometrics Trillium 240 generation 1 244 s / 0.0041 Hz 1197 V/M/S RESP.XX.NS122..BHZ.Trillium240_g1.244.1197 Nanometrics TA. T240-OBS1,T240-OBS2,T240-SV1
Nanometrics Trillium 240 generation 2 244 s / 0.0041 Hz 1189 V/M/S RESP.XX.NS123..BHZ.Trillium240_g2.244.1189 Nanometrics TA. T240-OBS1,T240-OBS2,T240-SV1
Nanometrics Trillium 240 244 s / 0.0041 Hz 1500 V/M/S RESP.XX.NS541..BHZ.Trillium240.244.1500 Nanometrics T240-SV1-1500
Nanometrics Trillium 360 373 s / 0.0027 Hz 1100 V/M/S RESP.XX.NS542..BHZ.Trillium360.373.1100 Nanometrics T360-B1/360-BH1,T360-PH1,T360-SV1
Nanometrics Trillium 360-GSN 360 s / 0.003 Hz 1999.5 V/M/S RESP.XX.NS696..BHZ.Trillium360GSN.360.1999 Nanometrics T360-PH1-GSN,T360-BH1-GSN,T360-SV1-GSN

Nanometrics, Mary Templeton 3/4/2022