REF TEK RT147 Accelerometer Response

RT147 Sensitivities

Nominal sensitivity in V/m/s**2 is

G in V/m/(s*s) = [Full scale voltage / Clip level] / [9.80665 m/(s**2)].

The responses here apply to the uniaxial (1) and triaxial (3) versions.

Manufacturer Model Period / Frequency Sensitivity (V/m/s**2) Full Scale Voltage Clip Level RESP Filename Source Comments
REF TEK RT147 0-0.006 s / DC->150 Hz 0.25493 V/M/S**2 +/-10V +/-4g RESP.XX.NS137..BNZ.RT147.DC_150.4G.10V REF TEK
REF TEK RT147A 0-0.006 s / DC->160 Hz 0.25493 V/M/S**2 +/-10V +/-4g RESP.XX.NS381..BNZ.RT147A.DC_160.4G.10V REF TEK

Mary Templeton 6/2/2016