Sercel L-22D Sensor Responses

Coil and shunt resistance values affect the sensitivity, damping and pole values. To calculate poles, zeros and sensitivities for L-22Ds built with other resistor values, click here.

Note:

These responses assume that the input resistance of the attached amplifier or datalogger is at least 2 orders of magnitude larger than the shunt resistance. If this is not the case, total damping will not be 70% and the poles will not describe the system accurately.

Manufacturer Model Frequency / Period Coil Resistance Shunt Resistance Sensitivity RESP Filename Source Comments
Sercel L-22D 2 Hz / 0.5 s 210 Ohms 857 Ohms 17.39 V/M/S RESP.XX.NS156..SHZ.L22D.210.857.2.17_4 Sercel
Sercel L-22D 2 Hz / 0.5 s 325 Ohms 1327 Ohms 21.64 V/M/S RESP.XX.NS157..SHZ.L22D.325.1327.2.21_6 Sercel
Sercel L-22D 2 Hz / 0.5 s 510 Ohms 2516 Ohms 30.3 V/M/S RESP.XX.NS158..SHZ.L22D.510.2516.2.30_3 Sercel
Sercel L-22D 2 Hz / 0.5 s 2200 Ohms 10854 Ohms 62.95 V/M/S RESP.XX.NS456..SHZ.L22D.2200.10854.2.62_9 Sercel
Sercel L-22D 2 Hz / 0.5 s 5470 Ohms 20000 Ohms 87.9 V/M/S RESP.XX.NS159..SHZ.L22D.5470.20000.2.87_9 Sercel PASSCAL
Sercel L-22D 2 Hz / 0.5 s 8540 Ohms 42133 Ohms 124.03 V/M/S RESP.XX.NS457..SHZ.L22D.8540.42133.2.124 Sercel