ref2segy: Version Number 94.010 State of Health 94:054:22:19:26:359 ST: 0029 054:22:19:26 RAM CLEARED 054:22:19:26 SERTSK RESET, Buffer contents lost. 054:22:19:37 DISK FORMAT CALLED 054:22:20:04 SCSI COMMAND COMPLETE 054:22:28:53 ACQUISITION STOP REQUESTED 054:22:28:54 PARAMETERS ERASED 054:22:28:55 OM 054:22:28:59 NU 054:22:29:05 NC1 054:22:29:09 NC2 054:22:29:14 NC3 054:22:29:19 NC4 054:22:29:24 NC5 054:22:29:29 NC6 054:22:29:38 DD1 054:22:29:56 DD2 054:22:30:01 XC 054:22:30:02 DSP REPORTS 0 24-BIT A/D BOARDS 054:22:30:04 PARAMETERS IMPLEMENTED 054:22:30:04 DSP CLOCK SET: OLD=00:000:00:00:00.669, NEW=94:054:22:30:04.007 054:22:30:04 DSP CLOCK DIFFERENCE: 4660204 SECS AND -662 MSECS 054:22:30:04 DSP CLOCK HAS CHANGED 2 TIMES 054:22:30:26 SCSI COMMAND COMPLETE 054:22:38:28 SYSTEM POWERUP 59: UNIT 29, CPU VER 02.53 054:22:38:28 MEMORY USED=1, AVAILABLE=4607, TOTAL=4608 054:22:38:28 BATTERY VOLTAGE = 00.0V, TEMPERATURE = -10C 054:22:38:28 DSP REPORTS 0 24-BIT A/D BOARDS 054:22:38:30 HARDWARE CONFIGURATION: 0100 State of Health 94:054:22:38:30:481 ST: 0029 054:22:38:30 ACQUISITION OFF AT POWERUP 054:22:38:30 POWERUP COMPLETE 054:22:38:31 DSP CLOCK SET: OLD=00:000:00:00:00.363, NEW=94:054:22:38:30.007 054:22:38:31 DSP CLOCK DIFFERENCE: 4660710 SECS AND -356 MSECS 054:22:38:31 DSP CLOCK HAS CHANGED 1 TIMES 054:22:38:38 NO EXTERNAL CLOCK INPUT 054:22:40:57 USER TIME SET 054:22:41:36 DSP CLOCK SET: OLD=94:054:22:40:58.007, NEW=94:054:22:41:36.007 054:22:41:36 DSP CLOCK DIFFERENCE: 38 SECS AND 0 MSECS 054:22:41:36 DSP CLOCK HAS CHANGED 2 TIMES 054:22:41:52 SYSTEM RESET 054:22:41:55 SYSTEM POWERUP 60: UNIT 29, CPU VER 02.53 054:22:41:55 MEMORY USED=2, AVAILABLE=4606, TOTAL=4608 054:22:41:55 BATTERY VOLTAGE = 00.0V, TEMPERATURE = -10C 054:22:41:55 DSP REPORTS 0 24-BIT A/D BOARDS 054:22:41:57 HARDWARE CONFIGURATION: 0100 054:22:41:57 ACQUISITION OFF AT POWERUP 054:22:41:57 POWERUP COMPLETE 054:22:41:58 DSP CLOCK SET: OLD=00:000:00:00:00.362, NEW=94:054:22:41:57.007 State of Health 94:054:22:41:58:047 ST: 0029 054:22:41:58 DSP CLOCK DIFFERENCE: 4660917 SECS AND -355 MSECS 054:22:41:58 DSP CLOCK HAS CHANGED 1 TIMES 054:22:42:05 NO EXTERNAL CLOCK INPUT 054:22:42:07 CPU SOFTWARE V02.53 054:22:42:07 ACQUISITION ENABLED WITH DELAY OF 00:00 Station Channel Definition 94:054:22:41:56:546 ST: 0029 Experiment Number = 2 Experiment Name = CAJON PASS PHASE II Comments - Station Number = 3 Station Name = CJBG -BLUE- Station Comments - DAS Model Number = DAS Serial Number = Experiment Start Time = Time Clock Type = NONE Clock Serial Number = Channel Number = 1 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - L22 Sensor Serial Number - 503-L Volts per Bit = 14.31 uV Comments - Channel Number = 2 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - Sensor Serial Number - Volts per Bit = 14.31 uV Comments - Channel Number = 3 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - Sensor Serial Number - Volts per Bit = 14.31 uV Comments - Channel Number = 4 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - 3-ESP Sensor Serial Number - T3185 Volts per Bit = 3.576 uV Comments - Channel Number = 5 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - Sensor Serial Number - Volts per Bit = 3.576 uV Comments - Station Channel Definition 94:054:22:41:56:546 ST: 0029 Experiment Number = 2 Experiment Name = CAJON PASS PHASE II Comments - Station Number = 3 Station Name = CJBG -BLUE- Station Comments - DAS Model Number = DAS Serial Number = Experiment Start Time = Time Clock Type = NONE Clock Serial Number = Channel Number = 6 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - Sensor Serial Number - Volts per Bit = 3.576 uV Comments - Wake-up Sequence Definition 94:054:22:41:56:546 ST: 0029 Power State : CP Recording Mode : SC Data Stream Definition 94:054:22:41:56:546 ST: 0029 Data Stream 1 500SPS Channels 456 Sample rate 500 samples per second Data Format 16 Filters Trigger Type EVT Trigger Channels 456 Minimum Number of channels 3 Trigger Window (seconds) 1.0 Pretrigger Length (seconds) 10 Posttrigger Length (seconds) 50.0 Record Length (seconds) 60 STA (seconds) 0.2 LTA (seconds) 10 Mean Average Length Trigger Ratio 6.0 Detrigger Ratio 6.0 LTA Hold Flag OFF Data Stream 2 250SPS Channels 123 Sample rate 250 samples per second Data Format 16 Filters Trigger Type EXT Pretrigger Length (seconds ) 10 Record Length (seconds) 60 Calibration Definition 94:054:22:41:56:546 ST: 0029 Start time : Year Day : : Repeat Interval Days : : Number of Repeats Length of CAL (seconds) Step OFF Freq OFF Noise OFF State of Health 94:054:22:42:08:435 ST: 0029 054:22:42:10 ACQUISITION STARTED 054:22:42:10 NO EXTERNAL CLOCK PRESENT 054:22:42:29 SCSI COMMAND COMPLETE 057:22:54:24 ACQUISITION STOP REQUESTED 057:22:54:24 ACQUISITION STOPPED 057:22:54:24 NO EXTERNAL CLOCK PRESENT 057:22:54:24 FINAL AUTO DUMP CALLED DAS: 0029 EV: 0002 DS: 2 FST = 1994:054:22:47:31:326 TT = 1994:054:22:47:29:652 NS: 15106 SPS: 250 ETO: 15272 EVT: 1 WARNING: ET FST & EH FST differ. Reporting EH FST DAS: 0029 EV: 0001 DS: 1 FST = 1994:054:22:47:18:802 TT = 1994:054:22:47:29:106 NS: 30544 SPS: 500 ETO: 0 DAS: 0029 EV: 0004 DS: 2 FST = 1994:056:13:00:10:214 TT = 1994:056:13:00:08:536 NS: 15106 SPS: 250 ETO: 15272 EVT: 3 WARNING: ET FST & EH FST differ. Reporting EH FST DAS: 0029 EV: 0003 DS: 1 FST = 1994:056:12:59:58:022 TT = 1994:056:13:00:08:026 NS: 60092 SPS: 500 ETO: 0 DAS: 0029 EV: 0006 DS: 2 FST = 1994:056:13:57:09:150 TT = 1994:056:13:57:07:473 NS: 15106 SPS: 250 ETO: 15272 EVT: 5 WARNING: ET FST & EH FST differ. Reporting EH FST DAS: 0029 EV: 0005 DS: 1 FST = 1994:056:13:56:56:958 TT = 1994:056:13:57:07:054 NS: 30378 SPS: 500 ETO: 0 DAS: 0029 EV: 0008 DS: 2 FST = 1994:056:14:05:15:862 TT = 1994:056:14:05:14:510 NS: 15106 SPS: 250 ETO: 15272 EVT: 7 WARNING: ET FST & EH FST differ. Reporting EH FST DAS: 0029 EV: 0007 DS: 1 FST = 1994:056:14:05:04:002 TT = 1994:056:14:05:14:200 NS: 30544 SPS: 500 ETO: 0 State of Health 94:057:22:54:37:243 ST: 0029 057:22:54:37 SOH LOG CLEARED 057:22:55:11 SCSI COMMAND COMPLETE 057:22:55:56 SCSI COMMAND COMPLETE 057:23:00:26 ACQUISITION STOP REQUESTED 057:23:00:27 PARAMETERS ERASED 057:23:00:28 OM 057:23:00:32 NU 057:23:00:38 NC1 057:23:00:42 NC2 057:23:00:47 NC3 057:23:00:52 NC4 057:23:00:57 NC5 057:23:01:01 NC6 057:23:01:11 DD1 057:23:01:28 DD2 057:23:01:33 XC 057:23:01:34 DSP REPORTS 0 24-BIT A/D BOARDS 057:23:01:36 PARAMETERS IMPLEMENTED 057:23:01:36 DSP CLOCK SET: OLD=00:000:00:00:00.460, NEW=94:057:23:01:36.007 057:23:01:36 DSP CLOCK DIFFERENCE: 4921296 SECS AND -453 MSECS 057:23:01:36 DSP CLOCK HAS CHANGED 2 TIMES 057:23:01:58 SCSI COMMAND COMPLETE 057:23:03:54 SYSTEM RESET 057:23:03:57 SYSTEM POWERUP 61: UNIT 29, CPU VER 02.53 057:23:03:57 MEMORY USED=2, AVAILABLE=4606, TOTAL=4608 057:23:03:57 BATTERY VOLTAGE = 00.0V, TEMPERATURE = -10C 057:23:03:57 DSP REPORTS 0 24-BIT A/D BOARDS 057:23:03:59 HARDWARE CONFIGURATION: 0100 State of Health 94:057:23:03:59:482 ST: 0029 057:23:03:59 ACQUISITION OFF AT POWERUP 057:23:03:59 POWERUP COMPLETE 057:23:04:00 DSP CLOCK SET: OLD=00:000:00:00:00.362, NEW=94:057:23:03:59.007 057:23:04:00 DSP CLOCK DIFFERENCE: 4921439 SECS AND -355 MSECS 057:23:04:00 DSP CLOCK HAS CHANGED 1 TIMES 057:23:04:07 NO EXTERNAL CLOCK INPUT 057:23:04:07 CPU SOFTWARE V02.53 057:23:04:07 ACQUISITION ENABLED WITH DELAY OF 00:00 Station Channel Definition 94:057:23:03:58:546 ST: 0029 Experiment Number = 2 Experiment Name = CAJON PASS PHASE II Comments - Station Number = 3 Station Name = CJBG -BLUE- Station Comments - DAS Model Number = DAS Serial Number = Experiment Start Time = Time Clock Type = NONE Clock Serial Number = Channel Number = 1 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - L22 Sensor Serial Number - 503-L Volts per Bit = 14.31 uV Comments - Channel Number = 2 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - Sensor Serial Number - Volts per Bit = 14.31 uV Comments - Channel Number = 3 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 8 Sensor Model - Sensor Serial Number - Volts per Bit = 14.31 uV Comments - Channel Number = 4 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - 3-ESP Sensor Serial Number - T3185 Volts per Bit = 3.576 uV Comments - Channel Number = 5 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - Sensor Serial Number - Volts per Bit = 3.576 uV Comments - Station Channel Definition 94:057:23:03:58:546 ST: 0029 Experiment Number = 2 Experiment Name = CAJON PASS PHASE II Comments - Station Number = 3 Station Name = CJBG -BLUE- Station Comments - DAS Model Number = DAS Serial Number = Experiment Start Time = Time Clock Type = NONE Clock Serial Number = Channel Number = 6 Name - Azimuth - Inclination - Location X - Y - Z - XY Units - Z Units - Preamplifier Gain = 32 Sensor Model - Sensor Serial Number - Volts per Bit = 3.576 uV Comments - Wake-up Sequence Definition 94:057:23:03:58:546 ST: 0029 Power State : CP Recording Mode : SC Data Stream Definition 94:057:23:03:58:546 ST: 0029 Data Stream 1 500SPS Channels 456 Sample rate 500 samples per second Data Format 16 Filters Trigger Type EVT Trigger Channels 4 Minimum Number of channels 1 Trigger Window (seconds) 1.0 Pretrigger Length (seconds) 10 Posttrigger Length (seconds) 50.0 Record Length (seconds) 60 STA (seconds) 0.2 LTA (seconds) 10 Mean Average Length Trigger Ratio 6.0 Detrigger Ratio 6.0 LTA Hold Flag OFF Data Stream 2 250SPS Channels 123 Sample rate 250 samples per second Data Format 16 Filters Trigger Type EXT Pretrigger Length (seconds ) 10 Record Length (seconds) 60 Calibration Definition 94:057:23:03:58:546 ST: 0029 Start time : Year Day : : Repeat Interval Days : : Number of Repeats Length of CAL (seconds) Step OFF Freq OFF Noise OFF State of Health 94:057:23:04:07:546 ST: 0029 057:23:04:09 ACQUISITION STARTED 057:23:04:09 NO EXTERNAL CLOCK PRESENT 057:23:04:31 SCSI COMMAND COMPLETE 062:17:36:13 AUTO DUMP CALLED DAS: 0029 EV: 0001 DS: 1 FST = 1994:057:23:07:51:827 TT = 1994:057:23:08:02:109 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0002 DS: 2 FST = 1994:057:23:07:51:735 TT = 1994:057:23:08:02:249 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0003 DS: 1 FST = 1994:058:05:00:27:199 TT = 1994:058:05:00:37:493 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0004 DS: 2 FST = 1994:058:05:00:27:439 TT = 1994:058:05:00:37:957 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0005 DS: 1 FST = 1994:058:21:29:32:199 TT = 1994:058:21:29:42:393 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0006 DS: 2 FST = 1994:058:21:29:32:439 TT = 1994:058:21:29:42:628 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0007 DS: 1 FST = 1994:059:05:41:04:091 TT = 1994:059:05:41:14:375 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0008 DS: 2 FST = 1994:059:05:41:03:999 TT = 1994:059:05:41:14:514 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0009 DS: 1 FST = 1994:061:03:36:22:827 TT = 1994:061:03:36:32:989 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0010 DS: 2 FST = 1994:061:03:36:22:735 TT = 1994:061:03:36:33:254 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0011 DS: 1 FST = 1994:061:10:16:24:435 TT = 1994:061:10:16:34:435 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0012 DS: 2 FST = 1994:061:10:16:24:343 TT = 1994:061:10:16:34:861 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0013 DS: 1 FST = 1994:061:23:08:39:351 TT = 1994:061:23:08:49:419 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0014 DS: 2 FST = 1994:061:23:08:39:591 TT = 1994:061:23:08:49:780 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0015 DS: 1 FST = 1994:062:08:42:04:843 TT = 1994:062:08:42:14:939 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0016 DS: 2 FST = 1994:062:08:42:04:751 TT = 1994:062:08:42:15:268 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0017 DS: 1 FST = 1994:062:09:54:35:703 TT = 1994:062:09:54:45:803 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0018 DS: 2 FST = 1994:062:09:54:35:943 TT = 1994:062:09:54:46:134 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0019 DS: 1 FST = 1994:062:14:09:09:031 TT = 1994:062:14:09:19:033 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0020 DS: 2 FST = 1994:062:14:09:09:271 TT = 1994:062:14:09:19:461 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0021 DS: 1 FST = 1994:062:17:35:15:699 TT = 1994:062:17:35:25:965 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0022 DS: 2 FST = 1994:062:17:35:15:607 TT = 1994:062:17:35:26:126 NS: 15106 SPS: 250 ETO: 0 State of Health 94:062:17:36:24:329 ST: 0029 062:17:36:24 SOH LOG CLEARED 062:17:37:51 AUTO DUMP COMPLETE 063:21:44:32 ACQUISITION STOP REQUESTED 063:21:44:33 ACQUISITION STOPPED 063:21:44:33 NO EXTERNAL CLOCK PRESENT 063:21:44:33 FINAL AUTO DUMP CALLED DAS: 0029 EV: 0023 DS: 1 FST = 1994:063:16:25:24:543 TT = 1994:063:16:25:34:855 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0024 DS: 2 FST = 1994:063:16:25:24:783 TT = 1994:063:16:25:35:302 NS: 15106 SPS: 250 ETO: 0 DAS: 0029 EV: 0025 DS: 1 FST = 1994:063:21:42:29:471 TT = 1994:063:21:42:39:571 NS: 30046 SPS: 500 ETO: 0 DAS: 0029 EV: 0026 DS: 2 FST = 1994:063:21:42:29:711 TT = 1994:063:21:42:39:901 NS: 15106 SPS: 250 ETO: 0