Nominal Response Library | |
---|---|
Element | datalogger |
Manufacturer | Quanterra |
Model | Q730 |
Below is some configuration-specific information to help you locate your instrument response.
FIR Filters
The responses given here are a subset of the possible Q730 responses. The FIR cascade for the Quanterra 730 is user configurable - the user can vary the filter sequence a great deal. Gains are user configurable as well. The responses given here represent only the default cascade described by the following macro:
STAGE=1,1000,0.002663,>>%CHAN_NAMES%
STAGE=3,200,FS2D5M,<1,>>%CHAN_NAMES%
STAGE=4,100,F96CM,<3,>%CHAN_NAMES%,>>%CHAN_NAMES%
STAGE=5,40,FS2D5,<3,>%CHAN_NAMES%
STAGE=6,20,FS2D5,<4,>%CHAN_NAMES%,>>%CHAN_NAMES%
STAGE=7,10,F96C,<6%M10_OUT%,>>%CHAN_NAMES%
%MFLAG%STAGE=8,5,F96C,<7,>%CHAN_NAMES%
STAGE=9,1,F260,<7,>%CHAN_NAMES%
The 0.1 and 0.01 Hz sample rates apply the Quanterra VLP and ULP fir filters to the default 1 Hz sample rate described in the macro.
Configurations
Showing 8 of 8
Final Sample Rate
|
Formats |
---|---|
datalogger_Quanterra_Q730_FR0.01 | |
0.01 Hz | |
datalogger_Quanterra_Q730_FR0.1 | |
0.1 Hz | |
datalogger_Quanterra_Q730_FR1 | |
1 Hz | |
datalogger_Quanterra_Q730_FR10 | |
10 Hz | |
datalogger_Quanterra_Q730_FR100 | |
100 Hz | |
datalogger_Quanterra_Q730_FR20 | |
20 Hz | |
datalogger_Quanterra_Q730_FR40 | |
40 Hz | |
datalogger_Quanterra_Q730_FR5 | |
5 Hz |