SAC Help

A forum for SAC users to exchange ideas and ask questions about SAC usage, installation, portability, etc.

Email address
sac-help@lists.ds.iris.edu
Type
Moderated by
IRIS Webmaster
Related tags
SAC Software SAC
October
September
August
July
June
May
April
March
February
January

Active Message Threads for August 2017

Josphat Mulwa
2017-08-29 17:58:24
This is is a follow-up of my email earlier this year in March 2017 regarding the above subject matter. I have successfully compiled and ran all STF library files apart from the attached one. Other than this one file, all the other files are working well. Any assistance regarding compiling and running the attached file is highly appreciated. Regards, Josphat ----------------------------------------- The University of Nairobi is ISO 9001:2008 certified. Website: http://www.uonbi.ac.ke/ Fa… [more]
No replies
Igor
2017-08-28 07:41:10 - 2017-08-28 22:42:14
Hello, I am using the ver 101.6a on Linux 64 bit. While displaying a long time series (4 days, 100 sps file in my case), I noticed that SAC cannot display the data properly in the second half of the file. It seems there is not enough precision on the x axis to handle the time. How do I correctly display the data? Please see the screenshots attached. I am comparing the same data obtained from different sources which can be ignored. Both time series display the same problems. Thank you, Igor
Replies
Nima Dolatabadi
2017-08-28 16:15:28 - 2017-08-28 22:11:53
I am using SEISMIC ANALYSIS CODE [06/12/2013 (Version 101.6)] on ubuntu 14.04 LTS, Recently I just used "picks on" option in order to get picks of time arrival every time I read and plot. But now this option is always on and every time I have to use "picks off" if I do not need it. In greater details the default option is always "picks on". now I want to know how can I change its default. regards
Replies
shubhangeeddn@gmail.com
2017-08-25 12:30:53
Can any one provide me Common Conversion Point (CCP) Stacking code that can be used for receiver function data (SAC format ) ? I will be thankful if any one can provide it.
No replies
Rehman .
2017-08-18 22:11:41 - 2017-08-19 00:42:56
Hello, I am getting following error . How to fix it. EVRESP ERROR: julian day must be an integer, found '0.01'
Replies
Brian Savage
2017-08-03 17:46:41
Léa, The data you are using is too long for the spectrogram command in 101.6a. This will be fixed in the next version. A quick fix is to reduce the size of your data by either - windowing you data or - downsampling your data (decimate 3) The data you are trying to take the spectrogram of is very long. It is long enough that the spectrogram function overflows the size of an integer (INT_MAX = 2147483647) while trying to determine the size of the spectrogram, as such it produces undefined … [more]
No replies
L??a PAUCHOT
2017-08-03 04:10:35
Helo, I’d like to know how I could solve my problem. I have the message : Segmentation fault (core dumped) when I’m using the function SPECTROGRAM. Thank you in advance for your reply Cordialy Léa Pauchot Provenance : Courrier<https://go.microsoft.com/fwlink/?LinkId=550986> pour Windows 10
Replies
Sharon Kedar
2017-08-01 03:19:09 - 2017-08-01 18:20:34
Hi, I am running SAC Version 101.6a on my Mac OS X 10.11.6. I am having problem with the LINE FILL option inside the Signal Stacking Subprocess (SSS). It runs fine outside SSS, but inside SSS the FILL does not work. It does not give an error message and seems to execute without a problem, but using the PlotRecordSection (PRS) command, the lines are not filled in. Any suggestions? Sharon Kedar
Replies
05:48:57 v.b3198453