The Titan accelerometer is available is several models, all of which are represented by the same responses. The Titan response is determined by the maximum full scale measurement range the user selects, whether +/-4g, +/-2g, +/-1g, +/0.5g +/-0.25g or +/-0.125g.
The Titan responses also apply to the accelerometer portion of the following integrated products, which contain a Titan accelerometer:
Nominal sensitivity in V/(m/s**2) is calculated by (Full scale voltage / Clip level) / 9.80665 m/s**2
Manufacturer | Model | Period / Frequency | Sensitivity (V/m/s**2) | Full Scale Voltage | Clip Level | RESP Filename | Source | Comments |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 16.32 V/M/S**2 | +/-20V Differential | +/-0.125g | RESP.XX.NS349..BNZ.Titan.DC_430.20V.0_125G | Nanometrics | |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 8.16 V/M/S**2 | +/-20V Differential | +/-0.25g | RESP.XX.NS125..BNZ.Titan.DC_430.20V.0_25G | Nanometrics | |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 4.08 V/M/S**2 | +/-20V Differential | +/-0.5g | RESP.XX.NS126..BNZ.Titan.DC_430.20V.0_5G | Nanometrics | |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 2.04 V/M/S**2 | +/-20V Differential | +/-1g | RESP.XX.NS127..BNZ.Titan.DC_430.20V.1G | Nanometrics | |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 1.02 V/M/S**2 | +/-20V Differential | +/-2g | RESP.XX.NS128..BNZ.Titan.DC_430.20V.2G | Nanometrics | |
Nanometrics | Titan | 0-0.002 s / DC->430 Hz | 0.510 V/M/S**2 | +/-20V Differential | +/-4g | RESP.XX.NS129..BNZ.Titan.DC_430.20V.4G | Nanometrics |
Nanometrics, Mary Templeton 10/26/2018