Questions? Contact us

DTCC SmartSolo-IGU-BD3C-5

Nominal Response Library
Element datalogger
Manufacturer DTCC
Model SmartSolo-IGU-BD3C-5

Below is some configuration-specific information to help you locate your instrument response.

Optional IIR Low Cut Filter:

The SmartSolo has an optional Low Cut Infinite Impulse Response (IIR) filter whose low-frequency corner can be set to 0.05 (DC Removal), 1, 2, 3, 4, 5, 6, 7, 8, 9 or 10 Hz, or can be Disabled (Off). The responses given here include the DC Removal, 1 Hz and Disabled options. If you have chosen another setting for this filter, you will need to choose either the 1 Hz or DC Removal response and replace the pole value for this stage with (2 * pi * fc) where fc is your selected corner frequency.

Configurations

Updating...

Showing 32 of 32

Preamp Db
Final Sample Rate
Final Filter Phase
DC Filter
Output Units
Formats
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR1000_FPLP_DFOff_OUcount
0 1000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR1000_FPMP_DFOff_OUcount
0 1000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR100_FPLP_DFOff_OUcount
0 100 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR100_FPMP_DFOff_OUcount
0 100 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR125_FPLP_DFOff_OUcount
0 125 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR125_FPMP_DFOff_OUcount
0 125 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR2000_FPLP_DFOff_OUcount
0 2000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR2000_FPMP_DFOff_OUcount
0 2000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR250_FPLP_DFOff_OUcount
0 250 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR250_FPMP_DFOff_OUcount
0 250 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR4000_FPLP_DFOff_OUcount
0 4000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR4000_FPMP_DFOff_OUcount
0 4000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR500_FPLP_DFOff_OUcount
0 500 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR500_FPMP_DFOff_OUcount
0 500 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR50_FPLP_DFOff_OUcount
0 50 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD0_FR50_FPMP_DFOff_OUcount
0 50 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR1000_FPLP_DFOff_OUcount
6 1000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR1000_FPMP_DFOff_OUcount
6 1000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR100_FPLP_DFOff_OUcount
6 100 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR100_FPMP_DFOff_OUcount
6 100 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR125_FPLP_DFOff_OUcount
6 125 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR125_FPMP_DFOff_OUcount
6 125 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR2000_FPLP_DFOff_OUcount
6 2000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR2000_FPMP_DFOff_OUcount
6 2000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR250_FPLP_DFOff_OUcount
6 250 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR250_FPMP_DFOff_OUcount
6 250 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR4000_FPLP_DFOff_OUcount
6 4000 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR4000_FPMP_DFOff_OUcount
6 4000 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR500_FPLP_DFOff_OUcount
6 500 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR500_FPMP_DFOff_OUcount
6 500 Hz MP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR50_FPLP_DFOff_OUcount
6 50 Hz LP Off count
datalogger_DTCC_SmartSolo-IGU-BD3C-5_PD6_FR50_FPMP_DFOff_OUcount
6 50 Hz MP Off count
Questions? Contact us