Questions? Contact us

Nanometrics TitanEA

Nominal Response Library
Element datalogger
Manufacturer Nanometrics
Model TitanEA

Final Filter Phase

The operator can configure the digitizer to use linear-phase or minimum-phase decimation filters.

DC Filter

The Library includes a response for a final IIR DC removal filter with a low-frequency corner of 1 mHz (0.001 Hz) as an example. The filter corner can be set to any value of integer mHz between 1 and 1000 mHz. For other corner frequency values, set the pole for this filter instead to the selected corner frequency times 2 * pi.

Configurations

Updating...

Showing 60 of 60

Final Sample Rate
DC Filter
Final Filter Phase
Formats
datalogger_Nanometrics_TitanEA_FR1000_DF0.001_FPLinear
1000 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR1000_DF0.001_FPMinimum
1000 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR1000_DFOff_FPLinear
1000 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR1000_DFOff_FPMinimum
1000 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR100_DF0.001_FPLinear
100 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR100_DF0.001_FPMinimum
100 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR100_DFOff_FPLinear
100 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR100_DFOff_FPMinimum
100 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR10_DF0.001_FPLinear
10 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR10_DF0.001_FPMinimum
10 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR10_DFOff_FPLinear
10 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR10_DFOff_FPMinimum
10 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR125_DF0.001_FPLinear
125 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR125_DF0.001_FPMinimum
125 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR125_DFOff_FPLinear
125 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR125_DFOff_FPMinimum
125 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR1_DF0.001_FPLinear
1 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR1_DF0.001_FPMinimum
1 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR1_DFOff_FPLinear
1 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR1_DFOff_FPMinimum
1 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR2000_DF0.001_FPLinear
2000 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR2000_DFOff_FPLinear
2000 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR200_DF0.001_FPLinear
200 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR200_DF0.001_FPMinimum
200 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR200_DFOff_FPLinear
200 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR200_DFOff_FPMinimum
200 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR20_DF0.001_FPLinear
20 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR20_DF0.001_FPMinimum
20 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR20_DFOff_FPLinear
20 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR20_DFOff_FPMinimum
20 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR250_DF0.001_FPLinear
250 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR250_DF0.001_FPMinimum
250 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR250_DFOff_FPLinear
250 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR250_DFOff_FPMinimum
250 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR2_DF0.001_FPLinear
2 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR2_DF0.001_FPMinimum
2 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR2_DFOff_FPLinear
2 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR2_DFOff_FPMinimum
2 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR40_DF0.001_FPLinear
40 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR40_DF0.001_FPMinimum
40 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR40_DFOff_FPLinear
40 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR40_DFOff_FPMinimum
40 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR5000_DF0.001_FPLinear
5000 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR5000_DF0.001_FPMinimum
5000 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR5000_DFOff_FPLinear
5000 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR5000_DFOff_FPMinimum
5000 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR500_DF0.001_FPLinear
500 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR500_DF0.001_FPMinimum
500 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR500_DFOff_FPLinear
500 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR500_DFOff_FPMinimum
500 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR50_DF0.001_FPLinear
50 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR50_DF0.001_FPMinimum
50 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR50_DFOff_FPLinear
50 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR50_DFOff_FPMinimum
50 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR5_DF0.001_FPLinear
5 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR5_DF0.001_FPMinimum
5 Hz 0.001 Minimum
datalogger_Nanometrics_TitanEA_FR5_DFOff_FPLinear
5 Hz Off Linear
datalogger_Nanometrics_TitanEA_FR5_DFOff_FPMinimum
5 Hz Off Minimum
datalogger_Nanometrics_TitanEA_FR80_DF0.001_FPLinear
80 Hz 0.001 Linear
datalogger_Nanometrics_TitanEA_FR80_DFOff_FPLinear
80 Hz Off Linear
Questions? Contact us
11:49:10 v.22510d55