Questions? Contact us

Quanterra Q4120

Nominal Response Library
Element datalogger
Manufacturer Quanterra
Model Q4120

Below is some configuration-specific information to help you locate your instrument response.

FIR Filters

The responses given here are a subset of possible Q412x responses. The FIR cascade for the Quanterra 4120 is user configurable - the user can vary the filter sequence. Gains are user configurable as well. The responses given here represent the default cascade described by the following macro:

STAGE=1,2000,0.001663,>>%CHAN_NAMES% STAGE=2,400,FS2D5M,<1,>>%CHAN_NAMES% STAGE=3,200,F96CM,<2,>>%CHAN_NAMES% STAGE=4,100,F96CM,<3,>%CHAN_NAMES%,>>%CHAN_NAMES% STAGE=5,40,FS2D5,<3,>%CHAN_NAMES% STAGE=6,20,FS2D5,<4,>%CHAN_NAMES%,>>%CHAN_NAMES% STAGE=7,10,F96C,<6%M10_OUT%,>>%CHAN_NAMES% %MFLAG%STAGE=8,5,F96C,<7,>%CHAN_NAMES% STAGE=9,1,F260,<7,>%CHAN_NAMES%

The 0.1 and 0.01 Hz sample rates apply the Quanterra VLP and ULP fir filters to the default 1 Hz sample rate described in the macro.

Configurations

Updating...

Showing 8 of 8

Final Sample Rate
Formats
datalogger_Quanterra_Q4120_FR0.01
0.01 Hz
datalogger_Quanterra_Q4120_FR0.1
0.1 Hz
datalogger_Quanterra_Q4120_FR1
1 Hz
datalogger_Quanterra_Q4120_FR10
10 Hz
datalogger_Quanterra_Q4120_FR100
100 Hz
datalogger_Quanterra_Q4120_FR20
20 Hz
datalogger_Quanterra_Q4120_FR40
40 Hz
datalogger_Quanterra_Q4120_FR5
5 Hz